But technically the ada does not have a minimum space requirement for the overall size of an accessible bathroom.
Commercial handicap bathroom size.
7 0 x 5 9 40 25 square feet.
Kohler greenwich wall mounted vitreous china bathroom sink in white with overflow drain 76 84 76 84.
The measurement starts from the point where a person has 9 inch vertical clearance for their feet and 27 inch vertical clearance for their knees.
Minimum 60 inch 1525mm diameter or t shaped turning spaces are also required as well as an accessible lavatory restroom accessories and access aisles that meet 2010 ada and 2009 icc ansi standards.
Ada standards for accessible design can be downloaded from www ada.
The space can provide forward or parallel access to the bathroom equipment and part of the area can underneath the equipment as long as there is enough clearance for the knees and toes of the person in the wheelchair.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
Get free shipping on qualified ada compliant wall mount sinks or buy online pick up in store today in the bath department.
Meets both 1991 standards and 2010 standards.
Set your store to see local availability.
30 inch by 48 inch access to the sink the door can t swing into this rectangle.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
Or for answers to.
Within the space there must be a free and clear circle with a five foot radius to allow wheelchair users to perform a 360 degree turn.
The doorway should be unobstructed so that hardware and other items won t interfere with entry and exit.
Floor space guidelines the required minimum floor space for a handicapped accessible bathroom is 30 inches by 48 inches.
Grab bars must have round edges and must return to the wall or another anchor point so there are no exposed ends.
This plan shows an example of a single user toilet room that meets the minimum requirements of both the 1991 standards and 2010 standards.